Thanks for choosing HITECH ELEVATOR as your business partner Mitsubishi style Elevator Door System-center opening Elevator Door Operator FECO-01 Lift/Elevator Door Operator
1.1.1 Power supply
Single-phase AC power AC220V±10%,50Hz±5%. It is suggested to power the door operator by C45N with current 6A. The power cable: brown L, blue N,yellow green E 1.2 Connection of the coder
The cable for coder is equipped when product delivery. Just to make it connected with the controller tightly. 1.3 Cable for electric motor
The three-phase motor cable is equipped when product delivery. Just to make it connected with the controller tightly. 1.4 Input/output signal cable connection 1.4.1 input
There are four COM terminals for input. Each of them can be defined as any function in Group H of parameter table independently. The normal open and normal close can be defined at will. But they can not be defined repeatedly. Otherwise the system will report fault. The parameters H1to H4 correspond terminal H1-H4 respectively. The followings are default definitions: 1.4.1.1 Door close input the continuous signal on COM AND H1 1.4.1.2 Door open input the continuous signal on COM AND H2 1.4.1.3 Door slow close input the continuous signal on COM AND H3 Note: The power supply of input signal is from the controller and any other power supply should not be applied. 1.4.2 output
There are four pairs of independent relay contact for output(with capacity is 3A,30VDC/250VAC). Each pair of output terminal can be defined as any function in Group P of parameter table independently. Also the normal open and normal close can be defined at will. The parameters P1to P4 correspond terminal pair C1-P4 to C4-P4 respectively. The followings are default definitions: 1.4.2.1 The signal of door full close when the door is fully closed C1 communicates with P1; 1.4.2.2 The signal of door full open when the door is fully opened C2 communicates with P2; 1.4.2.3 Door failure signal If there is failure during door operation C3 communicates with P3; 1.4.2.4 System failure signal If there is failure in system C4 communicates with P4.
Porducts can be packed in wooden cases and carton box
Competitive Advantages Rich experience in elevator business with a professional team of elevator experts Good quality products with low sales price to help customer save the cost Cooperation with Chinese famous elevator parts manufacturers with low purchase price A wide range of products listed in our website. Easy access to the technical specifications and sales price Mission and Services To build up an one-stop elevator parts E-market for overseas buyers. To help customers to source the cheapest but quality elevator parts. To help customers to make a lift-parts package and ensure the timely delivery. To offer free consultance in regard to elevator technology and business. To develop and share market together with customers Contact us if you need more details on Lift Landing Door Operator Mitsubishi Style. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Elevator Automatic Door、Lift Car Door Operator. If these products fail to match your need, please contact us and we would like to provide relevant information.

Single-phase AC power AC220V±10%,50Hz±5%. It is suggested to power the door operator by C45N with current 6A. The power cable: brown L, blue N,yellow green E 1.2 Connection of the coder
The cable for coder is equipped when product delivery. Just to make it connected with the controller tightly. 1.3 Cable for electric motor
The three-phase motor cable is equipped when product delivery. Just to make it connected with the controller tightly. 1.4 Input/output signal cable connection 1.4.1 input
There are four COM terminals for input. Each of them can be defined as any function in Group H of parameter table independently. The normal open and normal close can be defined at will. But they can not be defined repeatedly. Otherwise the system will report fault. The parameters H1to H4 correspond terminal H1-H4 respectively. The followings are default definitions: 1.4.1.1 Door close input the continuous signal on COM AND H1 1.4.1.2 Door open input the continuous signal on COM AND H2 1.4.1.3 Door slow close input the continuous signal on COM AND H3 Note: The power supply of input signal is from the controller and any other power supply should not be applied. 1.4.2 output
There are four pairs of independent relay contact for output(with capacity is 3A,30VDC/250VAC). Each pair of output terminal can be defined as any function in Group P of parameter table independently. Also the normal open and normal close can be defined at will. The parameters P1to P4 correspond terminal pair C1-P4 to C4-P4 respectively. The followings are default definitions: 1.4.2.1 The signal of door full close when the door is fully closed C1 communicates with P1; 1.4.2.2 The signal of door full open when the door is fully opened C2 communicates with P2; 1.4.2.3 Door failure signal If there is failure during door operation C3 communicates with P3; 1.4.2.4 System failure signal If there is failure in system C4 communicates with P4.







Product Categories : Elevator Door System > Mitsubishi Elevator Style
Premium Related Products
Other Products
Hot Products
escalator RollerElevator key switch/push button key switchElevator gearless traction machine-Elevator traction machineTamagawa Rotary encoder ts5213n578Lift Elevator Door System/Selcom Elevator Mechanical Door Operator ECO HYDRA/ Landing Door DEVICEElevator Car Door Elevator Parts/lift car door mechanismStep elevator integrated controller/AS350escalator VVVF controller / NICE2000 controller Monarch/350V,5.5-30KWLift landing door operator, Mitsubishi styleElevator Guide Rail clips,lift partslift guide rail/T-type lift railsElevator traction machine/Geared machine/1000kgs loadElevator control system/VVVF/Monarch cabinet for MRElevator gearless traction machine/Hot sell type/with good price/MCG150Elevator call panel/with round buttonsafety sensor for elevator door